~700-1,000 W+ per GPU · copper microchannel single-chip · GB200/GB300 GPU packages
AI racks have moved from ~20 kW to 120 kW and beyond, past the point where air cooling is physically viable. Moyan Technology supplies the liquid-cooling hardware that makes dense AI racks possible — direct-to-chip (DTC) cold plates, coolant distribution units (CDUs), manifolds, rear-door heat exchangers and immersion systems — sourced direct from the Taiwan and China factories that build most of the world’s AI-rack thermal hardware.
Cooling is capacity-constrained, with 12–18 month lead times on cold plates, quick-disconnects and rack CDUs — a real reason to secure second-source Taiwan/China supply. Most of the category is quoted per project after a thermal assessment.
Products, capacities and indicative anchors are in the catalog table on this page (stamped “as of” a date; most systems are project/RFQ).
Cool your GPU racks and design alongside racks & chassis and power.
Why is liquid cooling mandatory for AI racks? Air tops out around 30–41 kW per rack; GB200 NVL72 racks reach ~120–132 kW and next-gen platforms push toward 200–250 kW. Direct-to-chip liquid removes heat far more effectively.
What is a CDU? A Coolant Distribution Unit circulates and conditions coolant between the facility and the rack loop, in in-rack, row-based or liquid-to-air forms, from ~250 kW to 2 MW.
Cold plate or immersion? Direct-to-chip cold plates are the NVIDIA-specified default for rack-scale AI; immersion is a chip-agnostic alternative. We supply both and can advise per site.
How are cooling systems priced? Turnkey CDUs, loops and immersion pods are quoted per kW / per project after a thermal assessment; component anchors are indicative.
~700-1,000 W+ per GPU · copper microchannel single-chip · GB200/GB300 GPU packages
embedded/microchannel cooling channel · high power density, leak-tested
large-scale copper plate · high-compute 6+ GPU servers
up to 250 kW · liquid-to-liquid, up to 98% heat capture · 45C warm water · 2N/N+1 · Redfish/SNMP; EIA & OCP racks
250 kW · up to 400 L/min · L2L; PG25/treated water · 1-2 dense racks · leak detection + BMS/DCIM
~200 kW class · rack-level L2L
>240 kW in 2-rack footprint · cools up to 4x GB200 racks; no facility water needed
2 MW (2,269 kW @ 4C approach) · L2L, 1.2 LPM/kW · up to 12x 120 kW GB200 NVL72 racks · 25-micron
800 kW L2L · <=1200 L/min/pump; 950 L/min N+N · PG <=20% pri / <=30% sec · SNMP v3/Modbus
vertical supply+return rails · blind-mate/UQD quick-disconnects · 1.5-3.0 bar · GB200/GB300 NVL72 (~126-250 QD pair…
liquid-to-air RDHx · M8 5-17 kW -> M16 55-75 kW/rack · 42U/48U; facility-water fed
up to 75 kW/rack · rack-agnostic · 100 kW+ GPU brownfields
full-server dielectric submersion · up to ~250 kW/rack · ~1.03-1.06
200 kW · immersion liquid-cooled cabinet, low-noise
640 kW · two-phase dielectric phase-change; container/high-density
Send your part list or target spec for an indicative, itemized quote.
Request a quote